A certificate of analysis (COA) is the laboratory's own record of what it measured in a sample. Reading one takes five checks: who tested it, which sample, which method, what the units mean, and how the result compares with a limit.
This guide uses Ayor batch B251014: heavy metals AR-25-UD-498925-01 and microbiology AR-25-UD-509717-01 from Eurofins Food Testing UK Ltd (UKAS 0342), and fulvic acid report 2511-822 from BECS Analytics (Pvt) Ltd (PNAC ISO/IEC 17025:2017, Lab 316). All three PDFs are public.
Ayor Health sells pure Himalayan shilajit resin in the UK: £34.99 (20g), £49.99 (30g), £69.99 (50g). Every batch is independently tested by Eurofins UK and the reports are published in full at /lab-results.
Look for a named laboratory and an accreditation number. UKAS is the UK's national accreditation body; a UKAS number (Eurofins Food Testing UK is 0342) means the lab's methods are independently assessed. ISO/IEC 17025 is the international standard for testing laboratories, used by accreditation bodies worldwide (BECS Analytics holds it through PNAC, Pakistan's accreditation body).
An unnamed "partner lab" or a report from the brand itself is not independent evidence.
Each report has its own reference and date (for example AR-25-UD-498925-01, issued 12 November 2025). The brand should connect that reference to a batch code printed on your jar. Ours is B251014, and the verify page shows which certificates belong to it.
A single old report cannot describe every jar sold since. Testing should be per batch.
"<10 cfu/g" means below the lowest amount the method can reliably report, not zero. "Not detected in 25 g" for salmonella means none was found in a 25 gram sample, which is how food safety tests for it. Both are normal ways to report a clean result.
A named, accredited laboratory (for example a UKAS number or ISO/IEC 17025 accreditation), a certificate reference and date, a sample or batch reference, the test method, and results for lead, cadmium, mercury, arsenic and microbiology. For fulvic acid, the method should be stated, ideally ISO 19822:2018.
The "<" sign means the result was below the lowest amount the method can reliably report. It is not the same as zero, but it is a normal way of reporting a clean result. cfu/g stands for colony-forming units per gram, a count of living microbes that grew during the test.
Multiply the mg/kg result by your serving size in milligrams, then divide by 1,000. The answer is in micrograms. For example, lead at 0.335 mg/kg in a 300 mg serving is 0.101 micrograms.